For technical clarification, you will find below the individual descriptions relating to rotary table element s referred to in this catalogue.
The clamping torque means the efficacy of the clamping mechanism, the clamping force of the worm gear is excluded.
This allowable worm wheel torque is equal to the allowable torque for the worm wheel when the table rotation speeds is 1 min-1.
The inspection presentation of ISO 230-2 is based on continuously 5 revolutions of repeatedly clockwise and counter-clockwise test, to diagnose unidirectional systematic positioning deviation.
The inspection presentation of ISO 230-2 based on continuously 5 revolutions of repeatedly clockwise and counter-clockwise test, to diagnose nidirectional systematic repeatability of positioning deviation.
ISO 230-2 Norm (equal to JIS B 6192) |
Accuracy Inspection upon ISO 230-2 international norm is operated with 5 continuous runs in clockwise and counterclockwise test.
JIS B 6330 Norm in Single Run |
Simplified inspection norm without number of laps indicated.